Sterilizer Checks

Become a part of the BMET community & join our brand new forums to connect!

Routine maintenance tests for hospital sterilizers are essential to ensure their proper functioning and efficacy in sterilizing medical equipment and instruments. These tests help identify any issues or deviations from optimal performance, allowing for timely corrective action and preventive maintenance. Here are some required routine maintenance tests for hospital sterilizers:

  1. Biological Indicator Testing: Perform routine biological indicator (BI) testing to verify the sterilization efficacy of the sterilizer. BIs contain a known population of resistant microorganisms (e.g., Geobacillus stearothermophilus spores) and are placed inside the sterilizer during a sterilization cycle. After the cycle, the BI is incubated to assess microbial growth, confirming sterilization effectiveness.
  2. Chemical Indicator Monitoring: Monitor the sterilization process using chemical indicators, such as internal and external indicator strips or tapes. Chemical indicators change color when exposed to specific sterilization conditions (e.g., temperature, steam, or chemical vapor), providing a visual indication of cycle completion.
  3. Cycle Parameters Verification: Regularly verify and document the critical parameters of sterilization cycles, including temperature, pressure, and cycle duration. Use calibrated thermometers, pressure gauges, and timers to ensure accurate measurement and control of cycle parameters.
  4. Leak Testing: Conduct leak testing to identify any leaks or defects in the sterilizer’s chamber, door seals, and plumbing connections. Use a leak detector or pressure decay test to assess the integrity of the sterilizer’s containment system and prevent steam or gas leaks during sterilization cycles.
  5. Steam Quality Testing: Assess the quality of steam produced by the sterilizer to ensure optimal sterilization conditions. Measure steam temperature, pressure, and moisture content using steam quality testing equipment. Verify that steam parameters meet the requirements for effective sterilization.
  6. Routine Maintenance Inspections: Perform routine visual inspections of the sterilizer’s components, including chamber, door seals, filters, and plumbing connections. Check for signs of wear, corrosion, or damage that may affect sterilization performance. Clean or replace worn-out or damaged parts as needed.
  7. Calibration of Instruments: Calibrate sterilizer instruments and monitoring devices, such as temperature sensors, pressure gauges, and timers, on a regular basis. Ensure that calibration procedures are performed by qualified personnel using traceable standards and documentation.
  8. Water Quality Assessment: Assess the quality of water used in the sterilizer’s steam generation system. Monitor water purity, hardness, and conductivity to prevent scale buildup, corrosion, and microbial contamination in the sterilizer chamber and plumbing.
  9. Documentation and Recordkeeping: Maintain comprehensive records of all sterilizer maintenance activities, including test results, calibration certificates, maintenance logs, and service reports. Document any deviations from standard procedures and corrective actions taken to address them.
  10. Manufacturer’s Recommendations: Follow the manufacturer’s recommendations and guidelines for routine maintenance, testing, and inspection of the sterilizer. Refer to the sterilizer’s operation and maintenance manual for specific instructions on maintenance procedures and frequency.

By conducting these required routine maintenance tests, healthcare facilities can ensure the safe and effective operation of hospital sterilizers, maintain compliance with regulatory standards (e.g., FDA, CDC, and AAMI), and protect patient safety by preventing healthcare-associated infections. Regular maintenance and testing help extend the lifespan of sterilization equipment and minimize the risk of equipment failure or malfunction during critical sterilization processes.