Electroencephalography, commonly referred to as EEG, is one of the oldest and most clinically significant neurodiagnostic technologies still in routine use today. Unlike imaging modalities such as CT or MRI that visualize anatomical structures, EEG focuses on physiological function by measuring the electrical activity generated by neurons in the brain. For biomedical equipment technicians, EEG systems represent a different type of challenge than large imaging platforms. They are lower power, non-ionizing, and mechanically simple, but they demand an exceptional understanding of low-level bioelectric signals, noise suppression, patient safety, and signal integrity. Because EEG signals are extremely small and easily contaminated, many problems that appear “clinical” are in fact equipment, cabling, grounding, or environmental issues that fall squarely into the BMET domain.


Historical background

The history of EEG begins in the late nineteenth and early twentieth centuries with early explorations into bioelectricity. Scientists had already discovered that nerves and muscles generate electrical signals, but it was not until 1924 that German psychiatrist Hans Berger successfully recorded the first human electroencephalogram. Berger used surface electrodes placed on the scalp and detected rhythmic electrical patterns that varied with mental state. His early work identified what would later be called alpha waves, establishing that the brain’s electrical activity could be measured noninvasively.

Initially, EEG recordings were crude and difficult to interpret. Early systems used galvanometers and ink-writing pens on moving paper, producing long paper traces that neurologists learned to interpret visually. Throughout the mid-twentieth century, EEG became a central tool in neurology, particularly for the diagnosis of epilepsy, sleep disorders, encephalopathies, and coma assessment. As electronics advanced, vacuum tubes were replaced by transistors, amplification improved, and filtering became more precise.

The transition from analog to digital EEG systems occurred gradually in the late twentieth century. Digital signal processing allowed long-term recordings, computerized storage, automated event detection, and more sophisticated analysis such as frequency decomposition and coherence mapping. Modern EEG systems are now fully digital, network-connected devices that integrate with hospital information systems, video monitoring, and remote interpretation platforms. From a BMET perspective, this historical progression explains why EEG devices may still vary widely in design, with some legacy analog concepts persisting in modern digital packaging.


How EEG works: physics and signal acquisition

EEG measures the summed electrical activity of large populations of cortical neurons. Individual neurons generate action potentials, but EEG primarily reflects synchronized postsynaptic potentials occurring in pyramidal cells oriented perpendicular to the cortical surface. These electrical potentials propagate through brain tissue, cerebrospinal fluid, skull, and scalp, where they can be detected by surface electrodes.

The voltages involved are extremely small, typically in the range of microvolts. Because of this, EEG systems must employ very high-gain amplifiers with exceptional noise rejection. The fundamental physics is not based on radiation or imaging, but on biopotential measurement, similar in concept to ECG but far more susceptible to interference. EEG signals are frequency-dependent, commonly categorized into bands such as delta, theta, alpha, beta, and gamma, each associated with different physiological and pathological states.

From a BMET’s standpoint, understanding EEG physics means understanding that almost everything is a potential noise source. Power-line interference, poor electrode contact, cable motion, muscle activity, eye movement, and even nearby equipment can overwhelm true cerebral signals. Unlike CT, where a failed subsystem often produces a hard fault, EEG problems often manifest as subtle distortions, baseline drift, or excessive noise that requires careful troubleshooting rather than part replacement.


Electronic subsystems and signal processing

An EEG system consists of electrodes, lead wires, a patient interface box (often called a headbox), differential amplifiers, analog-to-digital converters, a processing computer, and display and storage software. Each of these subsystems plays a critical role in signal integrity.

Electrodes are typically made of silver-silver chloride and are placed on the scalp using standardized montages such as the international 10–20 system. The electrode-skin interface is one of the most common sources of problems. High impedance, dried conductive gel, or corroded electrodes can severely degrade signal quality. Lead wires connect the electrodes to the headbox, and these cables must be shielded, flexible, and mechanically robust to minimize motion artifacts.

The headbox contains the first stage of amplification and often includes impedance checking circuitry. EEG amplifiers are differential, meaning they measure the voltage difference between two inputs, which helps reject common-mode noise such as 50 or 60 Hz interference. The amplifiers must have very high input impedance and excellent common-mode rejection ratios. After amplification, signals pass through filters that limit bandwidth and remove unwanted frequencies, then into analog-to-digital converters that sample the signal for digital processing.

Modern EEG systems integrate closely with computers running specialized software for display, annotation, event marking, and analysis. Many systems also synchronize EEG data with video recordings, requiring precise time alignment. For BMETs, this means EEG support often extends into software updates, driver compatibility, storage management, and network connectivity, even though the underlying physiological measurement remains unchanged.


Where EEG is used in the hospital and clinical roles

EEG systems are most commonly found in neurology departments, epilepsy monitoring units, sleep laboratories, and intensive care units. In outpatient neurology clinics, routine EEG studies are performed to evaluate seizure disorders, altered mental status, and suspected encephalopathies. These studies may last from 20 minutes to an hour and are often performed with activation procedures such as hyperventilation or photic stimulation.

In epilepsy monitoring units, EEG systems are used for long-term continuous monitoring, sometimes over days, combined with video recording to correlate electrical activity with clinical events. These setups are more complex, involving multiple cameras, large data storage systems, and continuous operation. In ICUs, EEG may be used to monitor comatose patients, detect subclinical seizures, or assess brain function after cardiac arrest or trauma.

The clinical purpose of EEG is functional rather than anatomical. It helps clinicians diagnose epilepsy, classify seizure types, identify focal versus generalized brain dysfunction, assess sleep architecture, and monitor brain activity in critically ill patients. Because EEG findings directly influence treatment decisions, poor signal quality or system downtime can delay diagnosis or lead to misinterpretation.


Variations of EEG systems

EEG systems vary widely in configuration depending on clinical application. Routine EEG systems typically support 16 to 32 channels and are designed for short recordings. Long-term monitoring systems may support 64 channels or more and are optimized for continuous operation with minimal signal drift. Ambulatory EEG systems are portable, battery-powered units that patients wear at home, recording data for later analysis. These systems introduce additional challenges related to battery management, data integrity, and physical wear.

There are also specialized EEG variants such as quantitative EEG systems that perform advanced frequency analysis, and evoked potential systems that measure brain responses to specific stimuli. While the core biopotential measurement principles remain the same, each variation introduces different accessories, software modules, and maintenance considerations that BMETs must recognize.


Importance of EEG in the hospital

EEG occupies a unique niche in hospital diagnostics. It is noninvasive, relatively low cost compared to imaging modalities, and provides real-time insight into brain function. In emergency and critical care settings, EEG can be the only way to detect ongoing seizure activity in an unresponsive patient. In epilepsy care, EEG findings guide medication choices, surgical planning, and long-term management.

From an operational standpoint, EEG systems often run continuously for extended periods, especially in monitoring units. Reliability and signal stability are therefore critical. While a CT scanner failure is dramatic and obvious, EEG failures can be insidious, producing data that appears plausible but is actually corrupted. This places a special responsibility on BMETs to ensure not just uptime, but data quality.


Tools required for a BMET to work on EEG systems

Supporting EEG systems does not require heavy mechanical tools or high-voltage equipment, but it does require precision and attention to detail. A BMET should have a high-quality digital multimeter capable of measuring low resistance and continuity, as well as tools for inspecting and cleaning connectors and electrodes. Impedance meters or built-in impedance checking functions are essential for verifying electrode and cable integrity.

Cleaning supplies appropriate for delicate electrodes, such as manufacturer-approved solutions and nonabrasive materials, are important. Because EEG systems are sensitive to electromagnetic interference, understanding grounding and shielding principles is as important as having physical tools. On the IT side, BMETs should be comfortable working with computers, storage devices, and network connections, especially in long-term monitoring setups.


Preventive maintenance considerations

Preventive maintenance for EEG systems focuses on maintaining signal integrity rather than mechanical performance. Regular inspection and cleaning of electrodes and lead wires is critical to prevent corrosion and impedance issues. Cables should be checked for insulation breakdown, broken conductors, or loose connectors. Headboxes should be inspected for cracked housings or damaged ports.

Calibration and functional checks involve verifying that all channels respond appropriately, that filters operate as expected, and that impedance checks function correctly. Software maintenance includes ensuring that operating systems and EEG applications are updated according to vendor recommendations, while preserving compatibility with existing data and hospital systems. In long-term monitoring environments, storage capacity and backup procedures should also be reviewed as part of PM.


Common issues and BMET-level troubleshooting

The most common EEG complaints involve excessive noise, flat or missing channels, and intermittent signal loss. High noise levels are often caused by poor electrode contact, dried gel, or broken lead wires. Systematic troubleshooting usually begins by checking electrode impedance and swapping suspect cables or electrodes. Flat channels may indicate disconnected leads, failed amplifier inputs, or software configuration errors.

Motion artifacts can arise from cable movement, patient activity, or poorly secured electrodes. In these cases, improving cable management and electrode fixation can resolve the issue. Power-line interference often points to grounding problems, nearby electrical equipment, or damaged shielding. Because EEG systems are so sensitive, troubleshooting often requires collaboration with clinical staff to distinguish physiological artifacts from technical faults.


Clinical and technical risks

EEG systems are generally low risk compared to high-energy modalities, but risks still exist. Electrical safety is paramount because electrodes are in direct contact with the patient. Leakage currents must be kept extremely low, and isolation circuits must function properly. BMETs should ensure that EEG systems meet applicable electrical safety standards and that accessories are approved by the manufacturer.

Skin irritation or burns can occur if electrodes are improperly applied or if conductive materials dry out during long recordings. While this is primarily a clinical issue, equipment condition and accessory quality play a role. In long-term monitoring, cable entanglement or mechanical strain can also pose risks to patients, especially those who are confused or agitated.


Manufacturers, cost, and lifespan

EEG systems are produced by several well-established neurodiagnostic equipment manufacturers. These systems are significantly less expensive than large imaging modalities, with typical costs ranging from tens of thousands to a few hundred thousand dollars depending on channel count, software options, and monitoring capabilities. Ambulatory systems are generally less expensive, while full epilepsy monitoring setups with video integration are more costly.

The lifespan of an EEG system is often determined more by software support and accessory wear than by core hardware failure. With proper maintenance, amplifiers and headboxes can last many years. Electrodes and cables are consumable items and may require frequent replacement. Software obsolescence, operating system changes, and data storage demands often drive system upgrades before hardware fails.


Additional BMET considerations

Supporting EEG systems effectively requires close communication with neurologists and technologists. Subtle changes in signal quality may be clinically significant, and early reporting can prevent misdiagnosis. BMETs who develop expertise in EEG artifact recognition become valuable partners in the neurodiagnostic team.

EEG support also highlights the evolving role of the BMET as a hybrid technical and IT professional. Managing software, storage, and network connectivity is now as important as maintaining hardware. As EEG systems become more integrated with hospital networks and remote interpretation services, cybersecurity and data integrity considerations will continue to grow in importance.

In summary, EEG machines may appear simple compared to massive imaging systems, but they demand a refined technical approach. Mastery of EEG support involves understanding delicate bioelectric signals, maintaining impeccable signal paths, and ensuring patient safety. For BMETs, EEG represents a modality where attention to detail, interdisciplinary collaboration, and deep technical knowledge directly impact clinical care.nctioning.